Tailored protection for Edge computing
Three-phase UPS from 10 to 40 kVA/kW
The solution for
- Edge data centres
- Banks
- Telecom & media infrastructure
Advantages
Certified performance
- Full performance up to 40 °C without derating.
- Energy savings - without compromise: 96.5% efficiency in VFI.
- Up to 99% efficiency in “ECO” mode.
- Performance tested and verified by TÜV SÜD.
Embedded digital technology
- IoT-ready device for access to connected services.
- SOLIVE UPS mobile app for remote control and anomaly notification.
- Easy integration in LAN/WAN and virtual environments.
- Safe guided repair procedure.
Engineered for easy integration
- Fits within existing 19” cabinet.
- Lithium battery option.
- Fast recharge - even for very long back-up time.
Front access maintenance
- Easy maintenance - innovative brick swap architecture.
- Power brick replacement without rack disconnection.
- Minimized risk of human error.
- Rapid repairs: 5 time faster than legacy UPS.
Technical Data
Sn [kVA] |
|
|||||
Pn [kW] |
|
|||||
Input/Output - 3/1 |
|
|||||
Input/Output - 3/3 |
|
|||||
Parallel configuration | up to 6 units |
Input
Rated voltage | 400V 3ph+N |
Voltage tolerance | 240V to 480V |
Rated frequency | 50/60 Hz ± 10% |
Output
Power factor | 1 (according to IEC / EN 62040-3) |
Rated voltage |
1ph + N: 230 V (can be configured 220/240 V) 3ph + N: 400 V (can be configured 380/415 V) |
Rated frequency | 50/60 Hz |
Efficiency (TÜV SÜD verified)
Double conversion VFI mode | up to 96.5% |
Eco Mode | up to 99% |
Battery
Technologies | VRLA, NiCd, Li-Ion Battery |
Battery type | normal life - long life |
Configuration | external, separated or shared |
Reliability (MTBF)
MTBF (VFI) | >500,000 hrs (attested) |
MTBF (UPS) | >12,000,000 hrs (attested) |
Environment
Operating ambient temperature | full performance up to +40 °C (without specific conditions)> |
UPS Cabinet
19” rack height | 7U |
Dimension W x D x H | 444 x 820 x 305 mm |
Weight | 79kg max(1) |
Display | 3.5" |
Backup battery | external batteries |
Battery type | normal life - long life |
Degree of protection | IP20 |
Colours | RAL 7016 |
Advanced service performance
Life extension | service programme to avoid end of life |
Quick repair | 5 times less MTTR than legacy UPS by removable front access parts |
Standards
Safety | IEC/EN 62040-1, AS 62040.1.1, AS 62040.1.2 |
EMC | IEC/EN 62040-2, AS 62040.2 |
Performance | IEC/EN 62040-3, AS 62040.3 |
Environmental | full compliance with the RoHS EU directive |
Seismic compliance | on demand, in accordance with the Uniform Building Code UBC-1997 Zone 4 |
Product declaration | CE, RCM (E2376) |
(1) According to the model.